Drayton Wiser Binding This binding integrates the Drayton Wiser Smart Heating System (opens new window) .
The integration happens through the HeatHub, which acts as an IP gateway to the ZigBee devices (thermostats and TRVs).
Supported Things The Drayton Wiser binding supports the following things:
Bridge Label Description heathub HeatHub The network device in the controller that allows us to interact with the other devices in the system
Thing Label Description boiler-controller Boiler Controller The HeatHub attached to the boiler. This also acts as the hub device room Room Name Virtual groups of Room Thermostats and TRVs that can have temperatures and humidities roomstat Thermostat Wireless thermostats which monitor temperature and humidity, and call for heat itrv iTRV Wireless TRVs that monitor temperature, alter the radiator valve state and call for heat hotwater Hot Water Virtual thing to manage hot water states smart-plug Smart Plug Wireless plug sockets which can be remotely switched
Discovery The HeatHub can be discovered automatically via mDNS, however the secret cannot be determined automatically.
Once the secret has been configured, all other devices can be discovered by triggering device discovery again.
Thing Configuration HeatHub Configuration Once discovered, the HeatHub secret needs to be configured.
There are a few ways to obtain this, assuming you have already configured the system using the Wiser App.
Temporarily install a packet sniffing tool on your mobile device. Every request made includes the secret in the header. Enable setup mode on the HeatHub. Connect a machine temporarily to the WiserHeat_XXXXX network and browse to http://192.168.8.1/secret to obtain the secret. The refresh interval defines in seconds, how often the binding will poll the controller for updates.
The awaySetPoint defines the temperature in degrees Celsius that will be sent to the heathub when away mode is activated.
Channels Readonly Channels Boiler Controller Channel Item Type Description heatingOverride Switch State of the heating override button on the controller heatChannel1Demand Number:Dimensionless Current demand level of heating channel 1 heatChannel1DemandState Switch Is channel 1 calling the boiler for heat heatChannel2Demand Number:Dimensionless Current demand level of heating channel 2 heatChannel2DemandState Switch Is channel 2 calling the boiler for heat currentSignalRSSI Number:Power Relative Signal Strength Indicator currentWiserSignalStrength String Human readable signal strength currentSignalStrength Number Signal strength value that maps to qualityofservice icon
Hot Water Channel Item Type Description hotWaterOverride Switch State of the hot water override button on the controller hotWaterDemandState Switch Is hot water calling the boiler for heat hotWaterBoosted Switch Is hot water currently being boosted hotWaterBoostRemaining Number:Time How long until the boost deactivates in minutes
Room Channel Item Type Description currentTemperature Number:Temperature Currently reported temperature currentHumidity Number:Dimensionless Currently reported humidity (if there is a room stat configured in this room currentDemand Number:Dimensionless Current heat demand percentage of the room heatRequest Switch Is the room actively requesting heat from the controller roomBoosted Switch Is the room currently being boosted roomBoostRemaining Number:Time How long until the boost deactivates in minutes windowState Contact Is the window open or closed?
Room Stat Channel Item Type Description currentTemperature Number:Temperature Currently reported temperature currentHumidity Number:Dimensionless Currently reported humidity currentSetPoint Number:Temperature Currently reported set point currentBatteryVoltage Number:ElectricPotential Currently reported battery voltage currentWiserBatteryLevel String Human readable battery level currentBatteryLevel Number Battery level in percent currentSignalRSSI Number:Power Relative Signal Strength Indicator currentSignalLQI Number Link Quality Indicator currentWiserSignalStrength String Human readable signal strength currentSignalStrength Number Signal strength value that maps to qualityofservice icon zigbeeConnected Switch Is the roomstat joined to network
Smart TRV Channel Item Type Description currentTemperature Number:Temperature Currently reported temperature currentDemand Number:Dimensionless Current heat demand percentage of the TRV currentSetPoint Number:Temperature Currently reported set point currentBatteryVoltage Number:ElectricPotential Currently reported battery voltage currentWiserBatteryLevel String Human readable battery level currentBatteryLevel Number Battery level in percent currentSignalRSSI Number:Power Relative Signal Strength Indicator currentSignalLQI Number Link Quality Indicator currentWiserSignalStrength String Human readable signal strength currentSignalStrength Number Signal strength value that maps to qualityofservice icon zigbeeConnected Switch Is the TRV joined to network
Smart Plug Channel Item Type Description currentSignalRSSI Number:Power Relative Signal Strength Indicator currentSignalLQI Number Link Quality Indicator zigbeeConnected Switch Is the TRV joined to network plugInstantaneousPower Number:Power Current Power being drawn through the plug plugEnergyDelivered Number:Energy Cumulative energy drawn through the plug
Command Channels Boiler Controller Channel Item Type Description awayModeState Switch Has away mode been enabled ecoModeState Switch Has eco mode been enabled comfortModeState Switch Has comfort mode been enabled
Hot Water Channel Item Type Description manualModeState Switch Has manual mode been enabled hotWaterSetPoint Switch The current hot water setpoint (on or off) hotWaterBoostDuration Number Period in hours to boost the hot water
Room Channel Item Type Description currentSetPoint Number:Temperature The current set point temperature for the room manualModeState Switch Has manual mode been enabled roomBoostDuration Number Period in hours to boost the room temperature windowStateDetection Switch Detect whether windows are open
Room Stat Channel Item Type Description deviceLocked Switch Is the roomstat interface locked
Smart TRV Channel Item Type Description deviceLocked Switch Are the TRV controls locked
Smart Plug Channel Item Type Description plugOutputState Switch The current on/off state of the smart plug plugAwayAction Switch Should the plug switch off when in away mode manualModeState Switch Has manual mode been enabled deviceLocked Switch Are the Smart Plug controls locked
Known Responses for Specific Channels Channel Known responses currentWiserSignalStrength { "VeryGood", "Good", "Medium", "Poor", "NoSignal" } currentWiserBatteryLevel { "Full", "Normal", "TwoThirds", "OneThird", "Low", "Critical" }
Full Example .things file The name corresponds to the room name configured in the Wiser App.
It is not case sensitive.
The serialNumber corresponds to the device serial number which can be found on a sticker inside the battery compartment of the Smart Valves/TRVs, and behind the wall mount of the Room Thermostats.
.items file Sitemap